Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 834
Filtrar
1.
BMC Oral Health ; 24(1): 528, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702714

RESUMO

OBJECTIVES: To evaluate in the absence of teeth the variability of the mylohyoid line (ML), the microarchitecture of the adjacent bone, and whether the variable prominence/width of the ML is associated with the quality of the adjacent bone. METHODS: µCT scans of 28 human mandibles from anatomical specimens were analyzed. The following parameters were assessed in four edentulous areas (first and second premolar (PM), first, second, and third molar (M1/2/3)): ML width, cortical thickness (CtTh), average cortical- (Avg.Ct.BV/TV), and trabecular bone volume fraction (Avg.Tb.BV/TV). RESULTS: The ML width increased from the PM towards the M2 region, which also showed the highest variance (range: 0.4-10.2 mm). The CtTh showed a decrease in the M3 region, while Avg.Ct.BV/TV and Avg.Tb.BV/TV hardly differed among the regions. In the multivariable model on the effect of the various parameters on the ML width, only gender and tooth region were significant. Specifically, male specimens were associated with a wider ML width compared to female specimens and the M2 region was associated with a wider ML width compared to the other tooth regions. CONCLUSION: The ML width was not associated with the cortical and trabecular bone quality in the adjacent bone, while gender and tooth region had a significant effect. Specifically, the ML width was lower in female, but peaked in the M2 region with a median width of 3-4 mm. CLINICAL RELEVANCE: From a clinical point of view, it was confirmed that the ML is in general a highly variable structure, especially in the M2 region, but the ML width does not allow any conclusions on the bone quality. Altogether, this underlines the need for an individual and accurate diagnostic prior to any surgical intervention.


Assuntos
Mandíbula , Microtomografia por Raio-X , Humanos , Masculino , Feminino , Mandíbula/diagnóstico por imagem , Mandíbula/anatomia & histologia , Idoso , Processo Alveolar/diagnóstico por imagem , Processo Alveolar/patologia , Processo Alveolar/anatomia & histologia , Pessoa de Meia-Idade , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/patologia
2.
J Prosthet Dent ; 131(5): 904.e1-904.e10, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38472073

RESUMO

STATEMENT OF PROBLEM: Implant placement in the mandibular molar sites plays a crucial role in the restoration of edentulous mandibles. However, the evaluation of bone quantity before implant surgery using cone beam computed tomography (CBCT) is lacking. PURPOSE: The purpose of this clinical study was to evaluate CBCT images of edentulous patients to analyze the feasibility of implant placement in healed mandibular molar sites. MATERIAL AND METHODS: The CBCT data of 138 patients were analyzed in the sagittal plane for measurements of mandibular bone height (MBH), superior bone height (SBH), inferior bone height (IBH), buccal bone width (BBW), lingual bone width (LBW), and alveolar bone widths (ABWs). The edentulous sites were categorized according to the bone quantity and complexity of the implant surgery. Multivariate analysis of variance (MANOVA) was used to analyze the site, sex, and age-related variations. An independent t test was used to compare the difference of bone dimension in different sites and between sexes. One-way ANOVA followed by post hoc tests were used to analyze the difference between different age groups. Categorical variables were presented as number of events and percentages. The chi-squared test was used to compare categorical variables (α=.05). RESULTS: A total of 534 sites of interest were recorded, including 274 hemimandibles. A significant difference in BBW was found between the first and second molar sites. Men had higher MBH, SBH, IBH, and BBW than women. The distribution of implant surgical complexity in the conventional group was 63.5%, while the buccolingual tilted implant group accounted for 17.0%, and the complicated group accounted for 19.5%. Of the 274 hemimandibles, an implant could be placed directly at molar sites in 88% of situations. CONCLUSIONS: The BBW at the mandibular second molar site was greater than that at the first molar site. The amount of available bone in the SBH and BBW was greater in men than in women at the healed molar sites. Age did not significantly affect the complexity of the implant surgery. Implants can be placed directly in healed mandibular molar sites in most patients who require a complete arch mandibular implant-supported restoration.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Estudos de Viabilidade , Mandíbula , Dente Molar , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Masculino , Feminino , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Estudos Retrospectivos , Dente Molar/diagnóstico por imagem , Pessoa de Meia-Idade , Adulto , Idoso , Implantação Dentária Endóssea/métodos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Implantes Dentários
3.
J Dent ; 143: 104885, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38346663

RESUMO

OBJECTIVES: This article presents a novel complete-arch pillar system (CAPS) to register implant position and maxillomandibular relationship in one single visit for implant-supported fixed complete dental prostheses (IFCDPs). MATERIAL AND METHODS: The novel system presents a 3-unit toolset comprising intraoral scan bodies (ISBs), lateral pillar attachments (LPAs) and occlusal pillar attachments (OPAs). A 2-stage single visit workflow by an intraoral scanner (Trios 5) was introduced. The first stage "Screw-Scan-Done" was used to describe complete-arch intraoral implant scanning using LPAs. The second stage "Screw-Occlude-Done" involved virtual occlusal recording using OPAs. Two patients with one single edentulous arch were selected for this study. In the first patient, 6 bone level implants (Bone Level Tapered, Straumann) were placed in the edentulous maxilla at positions 12, 14, 16, 22, 24 and 26. In the second patient, 4 bone level implants (NobelActive CC, Nobel Biocare) were placed in the edentulous mandible at positions 32, 35, 42 and 45. A CAD-CAM procedure was initiated with the acquired IOS data to fabricate an interim IFCDP at the same day. Periapical radiographs were obtained of the implant-prosthetic connection of the definitive IFCDPs to verify the passive fit. Metrology software (Geomagic Qualify, 3D Systems - Matlab, Mathworks) was used to assess the implant analogs position in the 3D-printed casts used for fabricating the definitive IFCDPs. A quantitative occlusal relationship analysis was performed with IOS. RESULTS: Radiographic examination revealed no gaps at implant-prosthetic connection of the definitive IFCDPs. The 3D-printed casts showed an overall average distance deviation within the clinically acceptable range of errors of 150 µm. Quantitative occlusal relationship analysis with IOS showed well-distributed contacts. CONCLUSION: Within the limitations of this study, the following conclusions can be drawn: (1) A 3-unit toolset with ISBs, LPAs and OPAs allows to register the implant position and maxillomandibular relationship in one single visit; (2) the 2-stage clinical workflow with the CAPS system facilitates the IOS data acquisition for fabrication of an interim IFCDP at the same day; (3) a passive fit was demonstrated for the interim and the definitive IFCDPs. CLINICAL SIGNIFICANCE: The CAPS system can help clinicians to register the implant position and the maxillomandibular relationship in one single visit for the fabrication of an IFCDP.


Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Humanos , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Imageamento Tridimensional , Técnica de Moldagem Odontológica
4.
Clin Oral Implants Res ; 35(5): 560-572, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38421115

RESUMO

OBJECTIVES: The purpose of this in vitro study was to compare the trueness and precision of complete arch implant impressions using conventional impression, intraoral scanning with and without splinting, and stereophotogrammetry. MATERIALS AND METHODS: An edentulous model with six implants was used in this study. Four implant impression techniques were compared: the conventional impression (CI), intraoral scanning (IOS) without splinting, intraoral scanning with splinting (MIOS), and stereophotogrammetry (SPG). An industrial blue light scanner was used to generate the baseline scan from the model. The CI was captured with a laboratory scanner. The reference best-fit method was then applied in the computer-aided design (CAD) software to compute the three-dimensional, angular, and linear discrepancies among the four impression techniques. The root mean square (RMS) 3D discrepancies in trueness and precision between the four impression groups were analyzed with a Kruskal-Wallis test. Trueness and precision between single analogs were assessed using generalized estimating equations. RESULTS: Significant differences in the overall trueness (p = .017) and precision (p < .001) were observed across four impression groups. The SPG group exhibited significantly smaller RMS 3D deviations than the CI, IOS, and MIOS groups (p < .05), with no significant difference detected among the latter three groups (p > .05). CONCLUSIONS: Stereophotogrammetry showed superior trueness and precision, meeting misfit thresholds for implant-supported complete arch prostheses. Intraoral scanning, while accurate like conventional impressions, exhibited cross-arch angular and linear deviations. Adding a splint to the scan body did not improve intraoral scanning accuracy.


Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Fotogrametria , Fotogrametria/métodos , Humanos , Técnicas In Vitro , Modelos Dentários , Imageamento Tridimensional/métodos , Arcada Edêntula/diagnóstico por imagem , Implantes Dentários , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgia , Planejamento de Prótese Dentária
5.
J Oral Implantol ; 50(2): 104-110, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38353347

RESUMO

Accuracy is a necessity in implant impressions to fabricate accurately fitting implant-supported prostheses. This in vitro study aimed to explore the impact of the number of scan bodies on scanning quality by comparing scans of 2 vs 4 implants, and to determine if their accuracy and precision meets acceptable clinical threshold. Two mandibular edentulous models were used: one with 4-parallel implants (4-IM) and the other with 2-parallel implants (2-IM). Each model was scanned 10 times with an intraoral scanner, while reference scans were obtained with a high-precision laboratory scanner. The accuracy of test scans was evaluated by superimposing them onto reference scans and measuring 3D and angular deviations of the scan bodies. To assess the precision, the repeatability of the scans was analyzed by measuring the 3D SDs. Independent t test was used to compare angular deviations, the Mann-Whitney U test was used for 3D deviations and 3D SDs, and 1 sample t test was used for comparing means to the clinical threshold. Angular and 3D deviations were statistically not significant between the 2 groups (P = .054 and 0.143). 3D deviation values were higher than the 150-µm threshold for 2-IM (201 µm) and 4-IM (290 µm); angular deviation in 2-IM was 0.600 degrees and 0.885 degrees for 4-IM. There was no statistically significant difference in the precision of scans between the 2 groups. (P = .161). Although scanning quality improved when 2 scan bodies were used, the difference was not statistically significant. Moreover, full-arch implant scanning did not meet acceptable levels of accuracy and precision.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Humanos , Prótese Dentária Fixada por Implante , Mandíbula/diagnóstico por imagem , Imageamento Tridimensional , Técnicas In Vitro , Desenho Assistido por Computador , Arcada Edêntula/diagnóstico por imagem , Planejamento de Prótese Dentária , Modelos Dentários
6.
J Dent ; 139: 104747, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37863172

RESUMO

OBJECTIVES: The accuracy of 3-dimensional images produced by the intraoral scanner (IOS) is affected by scanning-aid materials. This in vitro study aimed to elucidate the influence of scanning-aid materials on the accuracy (trueness and precision) of digital scanning on the bilateral upper posterior edentulous jaw (Kennedy class I). METHODS: The asymmetrical bilateral upper posterior edentulous model (reference model) was generated using a 3D printer with three groups (application of TiO2 powder - composite and no-treatment control). The experimental scans were executed (n = 10 per group) using TRIOS3 (3shape), while one reference scan was obtained by an industrial scanner (Solutionix - C500). Values of trueness and precision were evaluated using the 3D superimposition method on mean deviation values. The accuracy was assessed using mean deviation values following the 3D superimposition method. RESULTS: IOS had high trueness (20.6 µm), and significant differences were found between the no-treatment and TiO2 groups. Considering the cut-off value of deviations as 300 µm for clinical acceptability, the analysis clarified the most variations in the control group. There was a significant difference between the no-treatment group and others in the maxillary tuberosity area relating to long-span edentulous. The composite group had the best precision values (1.1 µm). Significant differences were found between composite and TiO2 groups (2.7 µm). CONCLUSIONS: The bilateral upper posterior edentulous jaw digital impressions obtained using IOS were accurate. However, the digital images in the palate and maxillary tuberosity area related to long-span edentulous differed significantly. TiO2-containing powder and composite landmarks affected the accuracy and stability of the IOS. CLINICAL SIGNIFICANCE: Scanning aid materials can increase the accuracy of the bilateral upper posterior edentulous jaw scanning with IOS.


Assuntos
Técnica de Moldagem Odontológica , Arcada Edêntula , Humanos , Pós , Desenho Assistido por Computador , Modelos Dentários , Arcada Edêntula/diagnóstico por imagem , Imageamento Tridimensional
7.
Clin Oral Implants Res ; 34(11): 1278-1288, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37642206

RESUMO

OBJECTIVES: To evaluate the accuracy of implant placement using a dynamic navigation system in fully edentulous jaws and to analyze the influence of implant distribution on implant position accuracy. MATERIALS AND METHODS: Edentulous patients who received implant placement using a dynamic navigation system were included. Four to six mini screws were placed in the edentulous jaw under local anesthesia as fiducial markers. Then patients received CBCT scans. Virtual implant positions were designed in the planning software based on CBCT data. Under local anesthesia, implants were inserted under the guidance of the dynamic navigation system. CBCTs were taken following implant placement. The deviation between the actual and planned implant positions was measured by comparing the pre- and postsurgery CBCT. RESULTS: A total of 13 edentulous patients with 13 edentulous maxillae and 7 edentulous mandibles were included, and 108 implants were placed. The average linear deviations at the implant entry point and apex were 1.08 ± 0.52 mm and 1.15 ± 0.60 mm, respectively. The average angular deviation was 2.85 ± 1.20°. No significant difference was detected in linear and angular deviations between the maxillary and mandibular implants, neither between the anterior and posterior implants. CONCLUSIONS: The dynamic navigation system provides high accuracy for implant placement in fully edentulous jaws, while the distribution of the implants showed little impact on implant position accuracy.


Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea , Estudos Retrospectivos , Tomografia Computadorizada de Feixe Cônico , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgia , Computadores , Desenho Assistido por Computador , Imageamento Tridimensional
8.
Int J Implant Dent ; 9(1): 1, 2023 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-36595148

RESUMO

PURPOSE: This study investigates whether edentulous jaw sections in the planned implant position exhibit jaw contours funnel-shaped or exhibit pronounced retraction of the jaw (unusual jaw contours) in the transversal plane of the three-dimensional (3D) images, not visible in two-dimensional (2D) images. METHODS: A total of 335 patients with an edentulous section of the jaw that required dental implants were selected. Anonymised radiologic patients' data were collected, comprising cone-beam computed tomography (CBCT) images of the edentulous jaw sections. In the first stage, unusual jaw contours were examined, including funnel-shaped or pronounced retraction of the jaw and hypodense regions with an undercut and/or bone deficit. In the second stage, the variation in the height of the alveolar ridge between the lingual and buccal contour in the edentulous jaw sections was assessed. RESULTS: The CBCT images of an unusual jaw contour were observed in 8 cases (2.4%) in the maxilla on the left and 10 cases (3%) in the maxilla on the right. In the mandible, a jaw contour deviates in 39 cases (12.1%) on the left side and 39 cases (12.1%) on the right side. A height difference was detected in the upper jaw in 307 cases and the lower jaw in 265 cases. The discrepancy was 2.09 mm (± 2.25 mm) in the maxilla and 3.97 mm (± 3.45 mm) in the mandible. CONCLUSIONS: The CBCT scan provides useful information to avoid complications in the preoperative planning phase and surgical planning in implant dentistry.


Assuntos
Implantes Dentários , Arcada Edêntula , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Processo Alveolar/diagnóstico por imagem , Processo Alveolar/cirurgia , Arcada Edêntula/diagnóstico por imagem , Radiografia Panorâmica , Estudos Retrospectivos
9.
J Prosthet Dent ; 130(1): 111-118, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34799084

RESUMO

STATEMENT OF PROBLEM: The effect of additional reference objects on the accuracy of different intraoral scanners for partially and completely edentulous patients has not been investigated sufficiently. PURPOSE: The purpose of this in vitro study was to evaluate the effect of an additional reference object in the form of additional artificial landmarks on the trueness and precision of different intraoral scanners in partially and completely edentulous areas. MATERIAL AND METHODS: Partially and completely edentulous models with 2 and 4 implants (BLT, RC, Institut Straumann AG), respectively, were used in the study. For the digital scan, scan bodies (CARES Mono Scanbody) were attached, and reference data obtained by using industrial scanners. Ten digital scans of the same model were made with each intraoral scanner: PRIMESCAN, TRIOS 3, TRIOS 4, Carestream 3600, and Medit. Then, additional artificial landmarks were attached, and 10 more intraoral scans were made with each device. Computer-aided design files of the scan bodies were aligned to obtain 3-dimensional surfaces with reference and test scanners. Trueness and precision of distance, angulations, and vertical shift between scan bodies were estimated. The Mann-Whitney Wilcoxon or Student 2-sample t test was applied to estimate statistically significant differences between groups (α=.05). RESULTS: In the partially edentulous model, distance trueness mean ±standard deviation values ranged from -46.7 ±15.4 µm (TRIOS 3) to 392.1 ±314.3 µm (Medit) in models without additional artificial landmarks. When additional artificial landmarks were applied, trueness of distance mean ±standard deviation values ranged between -35 ±13 µm (TRIOS 4) and 117.7 ±232.3 µm (CARESTREAM). Trueness mean ±standard deviation values of angulation varied from -0.0 ±0.5 degrees (CARESTREAM) to 0.2 ±0.0 degrees (PRIMESCAN) without additional artificial landmarks and from 0.0 ±0.2 degrees (TRIOS 3) to 0.4 ±0.5 degrees (CARESTREAM) with additional artificial landmarks. Vertical shift trueness measurements varied from -108 ±47.1 µm (TRIOS 4) to 107.2 ±103.5 µm (Medit) without additional artificial landmarks and from -15.0 ±45.0 µm (CARESTREAM) to -86.9 ±42.1 µm (TRIOS 4) with additional artificial landmarks. The additional artificial landmark technique improved the trueness of all measured parameters for the 5 tested intraoral scanners. No statistically significant differences were found among models with or without additional artificial landmarks, except for Medit in all parameters and PRIMESCAN in angle measurements (P<.05). The best precision for distance was found with TRIOS 3 and with PRIMESCAN for angulation and vertical shift. Larger deviations were observed in the completely edentulous situation. The effect of additional artificial landmarks was limited when the accuracy parameters of digital scans were considered. CONCLUSIONS: Scans with and without additional artificial landmarks of partially edentulous conditions scanned by any of the intraoral scanners tested did not influence precision and trueness, except for Medit i500 in the distance and vertical shift parameters and CARESTREAM3600 in vertical shift. Precision and trueness of digital scans of completely edentulous areas were affected, except for Medit i500 for distance, PRIMESCAN and TRIOS 4 for angle, and all systems except TRIOS 4 for vertical shift precision.


Assuntos
Arcada Edêntula , Boca Edêntula , Humanos , Técnica de Moldagem Odontológica , Modelos Dentários , Imageamento Tridimensional , Arcada Edêntula/diagnóstico por imagem , Desenho Assistido por Computador , Boca Edêntula/diagnóstico por imagem
10.
J Prosthet Dent ; 129(6): 878-886, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34688477

RESUMO

STATEMENT OF PROBLEM: The buccal bone in an edentulous maxilla loses thickness over time because of physiological changes. However, the dimensional changes of the buccal bone in an edentulous maxilla with an implant-supported fixed dental prosthesis are unknown. PURPOSE: The purpose of this retrospective clinical study was to evaluate cone beam computed tomography (CBCT) images of the dimensional changes of the buccal bone in edentulous maxillae with complete arch telescopic-retained implant-supported fixed dental prostheses (CTI-FDPs) after 6 years by using a professional retrieval system. MATERIAL AND METHODS: This study included 17 participants with edentulous maxillae who had been provided with CTI-FDP with 121 taper joint implants. A three-dimensional radiographic analysis by using CBCT was performed at implant insertion (0 years) and after 6 years. Vertical and horizontal bone measurement values were evaluated. During horizontal bone thickness measurement, 4 different levels, 0, 2, 4, and 6 mm apical to the implant shoulder, were evaluated as bone value (BV)0mm, BV2mm, BV4mm, and BV6mm, respectively. The BVs were compared with the Wilcoxon signed-rank test and Kruskal-Wallis test (α=.05). In addition, the Spearman rank correlation coefficient was used to identify 0yBV factors that influence the 6yBVs. A nonlinear regression analysis was used to clarify the slopes of 0yBVs and 6yBV0mm. RESULTS: Significant decreases in vertical and horizontal BVs were found between 0 years and 6 years (P<.05). However, no significant difference was observed in bone loss at 6 years at any of the vertical and horizontal measurement points (P≥.05). When 0yBVs related to 6yBV0mm were analyzed, 0yBV0mm and 0yBV2mm showed strong correlations with 6yBV0mm (|r|≥.7). In the regression analysis, a 0yBV0mm of 0.58 mm and 0yBV2mm of 0.78 mm could be critical factors associated with a 6yBV0mm of 0 mm. A 6yBV0mm of 0yBV0mm more than 0.58 mm was significantly higher than a 6yBV0mm of 0yBV0mm less than 0.58 mm (P<.001). Moreover, a 6yBV0mm of 0yBV2mm more than 0.78 mm was significantly higher than a 6yBV0mm of 0yBV2mm less than 0.78 mm (P<.001). CONCLUSIONS: The buccal bone in an edentulous maxilla with fixed implant-supported prostheses lost significant vertical and horizontal bone thicknesses after 6 years. At implant insertion, both a 0.58-mm buccal bone on the platform and a 0.78-mm buccal bone at 2 mm apical to the implant shoulder are necessary for longer term maintenance of bone on the platform of implants specifically supporting CTI-FDPs.


Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Humanos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Estudos Retrospectivos , Planejamento de Prótese Dentária , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Seguimentos , Prótese Dentária Fixada por Implante , Implantação Dentária Endóssea/métodos
11.
J Prosthet Dent ; 130(2): 171-178, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34711405

RESUMO

Complete arch immediate-loading implant-supported prostheses can represent a major challenge for the patient and the dental team. Obtaining stable references and an accurate occlusal record after implant placement to provide an interim prosthesis is a difficult task and can deviate from the initial treatment plan. The described technique presents a fully digital protocol to provide an immediate complete arch implant-supported fixed interim prosthesis for edentulous patients by making postoperative cone beam computed tomography and intraoral digital scans that correlate with the previous plan.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Arcada Edêntula , Boca Edêntula , Humanos , Planejamento de Prótese Dentária , Carga Imediata em Implante Dentário/métodos , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgia , Prótese Total , Tomografia Computadorizada de Feixe Cônico , Prótese Dentária Fixada por Implante , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Implantação Dentária Endóssea/métodos
12.
J Prosthet Dent ; 130(2): 212-218, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34776266

RESUMO

STATEMENT OF PROBLEM: Clinical studies on the accuracy of the photogrammetric imaging technique for complete arch implant-supported fixed dental prostheses are lacking. PURPOSE: The purpose of this clinical study was to evaluate the accuracy (trueness) of photogrammetric imaging for complete arch implant-supported prostheses by comparing photogrammetric imaging with verified conventional splinted impressions. MATERIAL AND METHODS: Completely edentulous arches with at least 4 implants were included. Both photogrammetric imaging and conventional splinted impressions were performed in each jaw. The conventional casts were verified and scanned by using a laboratory scanner as the control. The distances and angulations between different implants (interimplant distances and interimplant angulations) were measured in all photogrammetric and conventional standard tessellation language (STL) files by using a reverse-engineering software program. The distance deviations between the photogrammetric and conventional impressions of the same participant were calculated as the primary outcome, and the angular deviations were obtained as the secondary outcome with descriptive analyses. The comparison between distance deviations and the clinically acceptable level of deviations (150 µm) was conducted by using the 1-sample t test. The effect of interimplant distances, interimplant angulations, and jaw (maxilla or mandible) on deviations was analyzed by using the Spearman correlation analysis, Kruskal-Wallis test, or Student t test, depending on the type of data (α=0.05 for all tests). RESULTS: Fourteen edentulous jaws were included. The overall distance deviation of photogrammetric imaging was 70 ±57 µm, significantly lower than the clinically acceptable level of misfit (150 µm; P<.001). The overall angular deviation was 0.432 ±0.348 degrees. The distance deviations were correlated with interimplant distances with a correlation coefficient (r) of 0.371 (P=.002). Interimplant angulation was not correlated with distance or angular deviations (P=.914, P=.914). Jaw was not correlated with distance or angular deviations either (P=.190, P=.209). CONCLUSIONS: The accuracy (trueness) of photogrammetric imaging of complete arch implant-supported prostheses was within a clinically acceptable range of errors. Distance deviations increased with greater interimplant distances. Interimplant angulations and jaw (maxilla or mandible) had no significant effect on the accuracy of photogrammetric imaging.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Técnica de Moldagem Odontológica , Modelos Dentários , Arcada Edêntula/diagnóstico por imagem , Fotogrametria , Desenho Assistido por Computador , Imageamento Tridimensional/métodos , Arco Dental/diagnóstico por imagem , Arco Dental/cirurgia
13.
J Dent ; 123: 104170, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35679989

RESUMO

OBJECTIVES: To compare the accuracy of dental implant placement using a dynamic navigation and a robotic system. METHODS: Eighty three-dimensional (3D) printed phantoms, including edentulous and partially edentulous jaws, were assigned to two groups: a dynamic navigation system (Beidou-SNS) group and a robotic system (Hybrid Robotic System for Dental Implant Surgery, HRS-DIS) group. The entry, exit and angle deviations of the implants in 3D world were measured after pre-operative plans and postoperative cone-beam computed tomography (CBCT) fusion. A linear mixed model with a random intercept was applied, and a p value <.05 was considered statistically significant. RESULTS: A total of 480 implants were placed in 80 phantoms. The comparison deviation of the dynamic navigation system and robotic system groups showed a mean (± SD) entry deviation of 0.96 ± 0.57 mm vs. 0.83 ± 0.55 mm (p=0.04), a mean exit deviation of 1.06 ± 0.59 mm vs. 0.91 ± 0.56 mm (p=0.04), and a mean angle deviation of 2.41± 1.42° vs. 1 ± 0.48° (p<0.00). CONCLUSIONS: The implant positioning accuracy of the robotic system was superior to that of the dynamic navigation system, suggesting that this prototype robotic system (HRS-DIS) could be a promising tool in dental implant surgery. CLINICAL SIGNIFICANCE: This in vitro study is of clinical interest because it preliminarily shows that a robotic system exhibits lower deviations of dental implants than a dynamic navigation system, in dental implant surgery, in both partially and completely edentulous jaws. Further clinical studies are needed to evaluate the current results.


Assuntos
Implantes Dentários , Arcada Edêntula , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea/métodos , Humanos , Imageamento Tridimensional , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Cirurgia Assistida por Computador/métodos
14.
J Dent ; 122: 104139, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35461974

RESUMO

OBJECTIVE: To assess the accuracy of a novel Artificial Intelligence (AI)-driven tool for automated detection of teeth and small edentulous regions on Cone-Beam Computed Tomography (CBCT) images. MATERIALS AND METHODS: After AI training and testing with 175 CBCT scans (130 for training and 40 for testing), validation was performed on a total of 46 CBCT scans selected for this purpose. Scans were split into fully dentate and partially dentate patients (small edentulous regions). The AI Driven tool (Virtual Patient Creator, Relu BV, Leuven, Belgium) automatically detected, segmented and labelled teeth and edentulous regions. Human performance served as clinical reference. Accuracy and speed of the AI-driven tool to detect and label teeth and edentulous regions in partially edentulous jaws were assessed. Automatic tooth segmentation was compared to manually refined segmentation and accuracy by means of Intersetion over Union (IoU) and 95% Hausdorff Distance served as a secondary outcome. RESULTS: The AI-driven tool achieved a general accuracy of 99.7% and 99% for detection and labelling of teeth and missing teeth for both fully dentate and partially dentate patients, respectively. Automated detections took a median time of 1.5s, while the human operator median time was 98s (P<0.0001). Segmentation accuracy measured by Intersection over Union was 0.96 and 0.97 for fully dentate and partially edentulous jaws respectively. CONCLUSIONS: The AI-driven tool was accurate and fast for CBCT-based detection, segmentation and labelling of teeth and missing teeth in partial edentulism. CLINICAL SIGNIFICANCE: The use of AI may represent a promising time-saving tool serving radiological reporting, with a major step forward towards automated dental charting, as well as surgical and treatment planning.


Assuntos
Arcada Edêntula , Boca Edêntula , Inteligência Artificial , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Processamento de Imagem Assistida por Computador , Arcada Edêntula/diagnóstico por imagem , Boca Edêntula/diagnóstico por imagem , Redes Neurais de Computação
15.
J Prosthet Dent ; 128(3): 468-478, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33612335

RESUMO

STATEMENT OF PROBLEM: The use of computer-aided design and computer-aided manufacturing (CAD-CAM) technologies is widely established, with single restorations or short fixed partial dentures having similar accuracy when generated from digital scans or conventional impressions. However, research on complete-arch scanning of edentulous jaws is sparse. PURPOSE: The purpose of this pilot in vitro study was to compare the accuracy of a digital scan with the conventional method in a workflow generating implant-supported complete-arch prostheses and to establish whether interference from flexible soft tissue segments affects accuracy. MATERIAL AND METHODS: An edentulous maxillary master cast containing 6 angled implant analogs was used and digitized with mounted scan bodies by using a high-precision laboratory scanner. The master cast was then scanned 10 times with 4 different intraoral scanners: TRIOS 3 with a complete-arch scanning strategy (TRI1) or implant-scanning strategy (TRI2), TRIOS Color (TRC), CEREC Omnicam (CER), and CEREC Primescan (PS). The same procedure was repeated with 4 different levels of free gingiva (G0-G3). Ten conventional impressions were obtained. Differences in implant position and direction were evaluated at the implant shoulder as mean values for trueness and interquartile range (IQR) for precision. Statistical analysis was performed by using the Kruskal-Wallis and post hoc Conover tests (α=.05). RESULTS: At G0, position deviations ranged from 34.8 µm (IQR 23.0 µm) (TRC) to 68.3 µm (12.2 µm) (CER). Direction deviations ranged from 0.34 degrees (IQR 0.18 degrees) (conventional) to 0.57 degrees (IQR 0.37 degrees) (TRI2). For digital systems, the position deviation ranged from 48.4 µm (IQR 5.9 µm) (PS) to 76.6 µm (IQR 8.1 µm) (TRC) at G1, from 36.3 µm (IQR 9.3 µm) (PS) to 79.9 µm (IQR 36.1 µm) (TRI1) at G2, and from 51.8 µm (IQR 14.3 µm) (PS) to 257.5 µm (IQR 106.3 µm) (TRC) at G3. The direction deviation ranged from 0.45 degrees (IQR 0.15 degrees) (CER) to 0.64 degrees (IQR 0.20 degrees) (TRC) at G1, from 0.38 degrees (IQR 0.05 degrees) (PS) to 0.925 degrees (IQR 0.09 degrees) (TRI) at G2, and from 0.44 degrees (IQR 0.07 degrees) (PS) to 1.634 degrees (IQR 1.08 degrees) (TRI) at G3. Statistical analysis revealed significant differences among the test groups for position (G0: P<.001; G1: P<.05; G2: P<.001; G3: P<.001) and direction (G0: P<.005; G1: P<.001; G2: P<.001; G3: P<.001). CONCLUSIONS: Without soft tissue interference, the accuracy of certain digital scanning systems was comparable with that of the conventional impression technique. The amount of flexible soft tissue interference affected the accuracy of the digital scans.


Assuntos
Implantes Dentários , Arcada Edêntula , Desenho Assistido por Computador , Arco Dental , Técnica de Moldagem Odontológica , Gengiva/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Arcada Edêntula/diagnóstico por imagem , Modelos Dentários
16.
J Oral Implantol ; 48(4): 263-268, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34091668

RESUMO

This study was designed to evaluate the accuracy of a novel computer-designed and selectively laser sintered surgical guide for flapless dental implant placement in the edentulous jaw. Fifty dental implants were placed in 11 patients with at least 1 totally edentulous jaw. Initially, cone-beam computed tomography (CBCT) was performed in each patient to define the virtual position of the dental implants based on the assessment of bone availability and the proposed dental prosthesis. After virtual planning, 3D surgical guides were printed using selective laser sintering. CBCT was repeated after the surgery, and the pre- and postoperative images were overlapped in computer-assisted design software to compare the planned and actual positions of the dental implants using a 1-sample t test. The mean ± angular standard deviation between the long axes of the planned and final dental implant positions was 4.58° ± 2.85°; the linear deviation in the coronal position was 0.87 ± 0.49 mm and in the apical region of the dental implants was 1.37 ± 0.69 mm. These differences were statistically significant (P < .001). The proposed modifications reduced the deviations, resulting in an improvement in the technique. We were able to place implants and temporary prostheses using the present protocol, taking into account the differences between the planned and final positions of the dental implants.


Assuntos
Implantes Dentários , Arcada Edêntula , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Computadores , Tomografia Computadorizada de Feixe Cônico/métodos , Implantação Dentária Endóssea/métodos , Humanos , Imageamento Tridimensional/métodos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Lasers , Planejamento de Assistência ao Paciente , Cirurgia Assistida por Computador/métodos
17.
Int J Oral Maxillofac Surg ; 51(2): 243-250, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34074574

RESUMO

The clinical outcomes of maxillary rehabilitation with the additively manufactured sub-periosteal jaw implant (AMSJI; CADskills BV) were evaluated in edentulous patients with a Cawood-Howell atrophy classification ≥5 in all regions of the maxilla. Fifteen consecutive patients were included in the study and followed up for 1 year. They were interviewed using a survey protocol and were examined clinically and radiographically preoperatively (T0) and at 1 (T1), 6 (T2), and 12 (T3) months after permanent upper prosthesis placement. The patients reported an increased oral health-related quality of life. The overall mean Oral Health Impact Profile-14 score at T0 was 17.20 (standard deviation (SD) 6.42). When results at T0 were compared to those at T1 (mean 8.93, SD 5.30), a statistically significant difference was seen (P = 0.001). At T3, the mean value was 5.80 (SD 4.18). Compared to T0, there was also a statistically significant difference at T3 (P = 0.001). General satisfaction based on the numerical rating scale was a mean 49.93 at T1, which was less than patient expectation prior to treatment at T0 (52.13). A higher overall value was seen at T3 (53.20) when compared to T0. Within the constraints of the short follow-up, the AMSJI appears to be a promising tool for patients with extreme jaw atrophy. The high patient expectations were met without complications.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Arcada Edêntula , Perda do Osso Alveolar/cirurgia , Implantação Dentária Endóssea , Prótese Dentária Fixada por Implante , Seguimentos , Humanos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Maxila/diagnóstico por imagem , Maxila/cirurgia , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
18.
Int J Oral Maxillofac Surg ; 51(2): 263-268, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33933335

RESUMO

The aim of this study was to evaluate a novel soft tissue-based method to register an intraoral scan (IOS) with a cone beam computed tomography (CBCT) scan. IOS and CBCT data were obtained from eight dentate patients (mean age 21±2 years; three male, five female) and 14 fully edentulous patients (mean age 56±9 years; eight male, six female). An algorithm was developed to create a soft tissue model of the CBCT scan, which allowed a soft tissue-based registration to be performed with the IOS. First, validation was performed on dentate jaws with registration of the palatal mucosal surface and accuracy evaluation at the level of the teeth. Second, fully edentulous jaws were registered using both the palatal and alveolar crest mucosal surfaces. Distance maps were created to measure the method accuracy. The mean registration error was 0.49±0.26mm for the dentate jaws. Registration of the fully edentulous jaws had a mean error of 0.16±0.08mm at the palate and 0.16±0.05mm at the alveolar crest. In conclusion, the high accuracy of this registration method may allow the digital workflow to be optimized when no teeth are available to perform a regular registration procedure.


Assuntos
Arcada Edêntula , Boca Edêntula , Adulto , Idoso , Algoritmos , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Imageamento Tridimensional , Arcada Edêntula/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Adulto Jovem
19.
J Prosthet Dent ; 128(6): 1165-1170, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33795160

RESUMO

The use of zygomatic implants to rehabilitate the severely atrophic maxilla has been well documented since first being introduced by Brånemark. Placement of zygomatic implants is technically complex, with catastrophic complications and numerous prosthetic challenges resulting from imprecise placement. The purpose of this report was to demonstrate a technique that allows transfer of the preoperatively planned sinus slot position to the surgical field by using cone beam computed tomography (CBCT) and an implant planning software program to fabricate a combined bone- and mucosa-supported 3D-printed surgical guide. This facilitates optimal zygomatic implant positioning and promotes favorable biomechanics with a predictable prosthetic outcome.


Assuntos
Implantes Dentários , Arcada Edêntula , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea/métodos , Cirurgia Assistida por Computador/métodos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Impressão Tridimensional , Mucosa/cirurgia , Zigoma/diagnóstico por imagem , Zigoma/cirurgia , Prótese Dentária Fixada por Implante , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia
20.
J Craniofac Surg ; 33(5): e488-e491, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34907950

RESUMO

ABSTRACT: The aim of this case series was to evaluate the long-term success rate of immediate occlusal loading of extrasinus zygomatic dental implants after a 3-year follow-up. The sample consisted of 31 patients (mean age of 64 years) with atrophic maxillae rehabilitated with 1 to 4 extrasinus zygomatic implants, placed unilaterally or bilaterally. All the patients received complete implant-supported dental prostheses with immediate loading by associating zygomatic implants with conventional implants. None of the procedures were associated with bone grafts. During the 3-year period of follow-up in the present study, all the patients attended clinical sessions and underwent radiographic exams every 6 months. In total 55 zygomatic and 69 conventional implants were placed, where 1 zygomatic and 2 conventional implants were lost, representing success rates of 98.18% and 97.20%, respectively. None of the studied patients had signs of sinusitis or changes in the maxillary sinuses. All the patients showed occlusal contact on natural antagonist teeth or implant-supported dental prostheses. Therefore, it was concluded that the use of exteriorized zygomatic implants with immediate loading represented a feasible option with high success rates for the treatment of atrophic maxilla.


Assuntos
Implantes Dentários , Arcada Edêntula , Atrofia/patologia , Implantação Dentária Endóssea/métodos , Prótese Dentária Fixada por Implante , Seguimentos , Humanos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Maxila/diagnóstico por imagem , Maxila/patologia , Maxila/cirurgia , Pessoa de Meia-Idade , Resultado do Tratamento , Zigoma/diagnóstico por imagem , Zigoma/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA